Mitsubishi Electronics FR-A700 Manual Do Utilizador
466
*1
These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 333 for RS-485 communication)
(Refer to page 333 for RS-485 communication)
*2
Validity and invalidity according to operation mode are as follows:
:Usable parameter
×
:Unusable parameter
Δ :Parameters available only during position control set by parameter
*3
" " indicates valid and "
×" indicates invalid of "parameter copy", "parameter clear", and "all parameter clear".
*4
Parameters can be used with conditions. Refer to page 203 for details.
*5
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication.
(Refer to page 328 for RS-485 communication)
(Refer to page 328 for RS-485 communication)
*6
When a communication option is installed, parameter clear (lock release) during password lock (Pr. 297
≠ 9999) can be performed only from the
communication option.
Symbols in the table indicate parameters which function when an option is mounted.
......FR-A7AX, ......FR-A7AY, .............FR-A7AR, .........FR-A7AP, ..........FR-A7AL,
.........FR-A7AZ, .........FR-A7AD,
......FR-A7NC, ......FR-A7NCE, .........FR-A7ND, .........FR-A7NL, .........FR-A7NP, .........FR-A7NS, .........FR-A7NF
Appendix 2 Control mode-based parameter (function) correspondence
table and instruction code list
Pa
ra
m
et
er
Name
Instruction
Code
* 1
Control Mode-based Correspondence Table
*2
Para
m
eter
C
op
y
*
3
Par
ame
ter Cl
ear
*3
Al
l Para
met
er
C
le
ar
*3
Re
a
d
Wr
it
e
Ex
te
nd
e
d
V/F
control
Advanced
magnetic
flux
vector
control
Vector control
Real sensorless
vector control
Speed
control
Torque
control
control
Position
control
Speed
control
Torque
control
control
0
Torque boost
00
80
0
×
×
×
×
×
×
1
Maximum frequency
01
81
0
2
Minimum frequency
02
82
0
×
3
Base frequency
03
83
0
×
×
×
×
×
×
4
Multi-speed setting (high speed)
04
84
0
Δ
5
Multi-speed setting (middle speed)
05
85
0
Δ
6
Multi-speed setting (low speed)
06
86
0
Δ
7
Acceleration time
07
87
0
Δ
8
Deceleration time
08
88
0
Δ
9
Electronic thermal O/L relay
09
89
0
10
DC injection brake operation
frequency
frequency
0A
8A
0
×
11
DC injection brake operation
time
time
0B
8B
0
×
12
DC injection brake operation
voltage
voltage
0C
8C
0
×
×
×
13
Starting frequency
0D
8D
0
×
14
Load pattern selection
0E
8E
0
×
×
×
×
×
×
15
Jog frequency
0F
8F
0
×
16
Jog acceleration/
deceleration time
deceleration time
10
90
0
×
17
MRS input selection
11
91
0
18
High speed maximum
frequency
frequency
12
92
0
×
×
×
×
×
19
Base frequency voltage
13
93
0
×
×
×
×
×
×
20
Acceleration/deceleration
reference frequency
reference frequency
14
94
0
Δ
21
Acceleration/deceleration
time increments
time increments
15
95
0
Δ
22
Stall prevention operation
level (torque limit level )
level (torque limit level )
16
96
0
×
×
23
Stall prevention operation
level compensation factor at
double speed
level compensation factor at
double speed
17
97
0
×
×
×
×
×
24
Multi-speed setting (speed
4)
4)
18
98
0
Δ
25
Multi-speed setting (speed 5)
19
99
0
Δ