Glossary
Appendix A
A–4
Free-run Stop
A method of stopping a motor, caused when the inverter simply 
turns OFF its motor output connections. This may allow the motor 
and load to coast to a stop, or a mechanical brake may intervene and 
shorten the deceleration time.
Frequency Setting
While frequency has a broad meaning in electronics, it typically 
refers to motor speed for variable-frequency drives (inverters). This 
is because the output frequency of the inverter is variable, and is 
proportional to the attained motor speed. For example, a motor with 
a base frequency of 60 Hz can be speed controlled with an inverter 
output varying form 0 to 60 Hz. See also Base FrequencyCarrier 
Frequency
, and Slip.
Harmonics
harmonic is a whole number multiple of a base of fundamental 
frequency. The square waves used in inverters produce high-
frequency harmonics, even though the main goal is to produce 
lower-frequency sine waves. These harmonics can be harmful to 
electronics (including motor windings) and cause radiated energy 
that interferes with nearby electronic devices. Chokes, line reactors, 
and filters are sometimes used to suppress the transmission of 
harmonics in an electrical system. See also Choke.
Horsepower
A unit of physical measure to quantify the amount of work done per 
unit of time. You can directly convert between horsepower and 
Watts as measurements of power.
IGBT
Insulated Gate Bipolar Transistor (IGBT) – A semiconductor 
transistor capable of conducting very large currents when in satura-
tion and capable of withstanding very high voltages when it is OFF. 
This high-power bipolar transistor is the type used in Hitachi invert-
ers. 
Inertia
The natural resistance a stationary object to being moved by an 
external force. See also Momentum.
Intelligent Terminal
A configurable input or output logic function on the Hitachi invert-
ers. Each terminal may be assigned one of several functions.
Inverter
A device that electronically changes DC to AC current through an 
alternating process of switching the input to the output, inverted and 
non-inverted. A variable speed drive such as the Hitachi L200 is 
also called an inverter, since it contains three inverter circuits to 
generate 3-phase output to the motor.
Isolation Transformer
A transformer with 1:1 voltage ratio that provides electrical isola-
tion between its primary and secondary windings. These are 
typically used on the power input side of the device to be protected. 
An isolation transformer can protect equipment from a ground fault 
or other malfunction of nearby equipment, as well as attenuate 
harmful harmonics and transients on the input power.