Smeg A5-6 Manual Do Utilizador

Página de 39
 
Instructions for the Installer
 
 
 
 
3.2 Burner and nozzle characteristics table 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG
 
 
G30/G31
  
28/37
 
mbar 
(drawing ref. X238) 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
Mm 
1/100 
Reduced 
flowrate 
(W) 
Flowrate  
g/h G30 
Flowrate  
g/h G31 
Auxiliary 
1.05 
50 
30 
360 
76 
75 
Semi rapid 
1.8 
65 
33 
450 
131 
129 
Rapid 
3.0 
85 
45 
750 
218 
215 
Fish Burner 
1.9 
68 
45 
800 
138 
136 
Ultra rapid 
3.9 
100 
68 
1600 
262 
257 
UR2 Inner ring 
1.0 
46 
30 
350 
73 
71 
UR2 Outer ring 
3.5 
68+68 
68 
1600 
284 
250 
 
 
 
 
 
Burner 
Rated  
heating  
capacity 
(kW) 
 
NATURAL GAS –
 
G20
  
20
 
mbar 
 
 
Nozzle diameter 
1/100 mm 
Drawing 
Ref. 
Reduced flowrate 
(W) 
Auxiliary 
1.05 
72  
(X) 
360 
Semi rapid 
1.8 
97  
(Z) 
450 
Rapid 
3.0 
115  
(Y) 
750 
Fish Burner 
1.9 
94  
(X) 
800 
Ultra rapid 
3.9 
126 
(K) 
1600 
UR2 Inner ring 
1.0 
  70 
(X) 
350 
UR2 Outer ring 
3.5 
102 +102 
(Z) 
1600 
 
 
3.3  Hob burner layout 
 
 
 
BURNERS 
 
1
 
Auxiliary 
2
 
Semi rapid 
3
 
Rapid 
4
 
Ultra rapid 
5
 
Fish 
6
 
UR2 Inner ring 
7
 
UR2 Outer ring 
 
51