Step 4: Gas Requirements and Hookup
Cooktops are shipped by the factory to operate on 
natural gas.They must be converted for use with 
propane. Verify the type of gas being used at the 
installation site matches the type of gas used by the 
appliance. 
If the location/job site requires conversion from 
natural gas to propane (LP), contact the dealer where the 
unit was purchased or contact Thermador. The field 
conversion kit for the Professional Cooktops in this series is 
Thermador Model PALPKITHC. Obey all instructions in this 
kit for correct conversion of the gas regulator and settings 
for the gas valves. Field conversion must be done by 
qualified service personnel only. 
Natural Gas Requirements: 
Inlet Connection: 1/2” NPT (min. 3/4” dia. flex line) 
Supply Pressure: 6” min. to 14” max. water column (14.9 to 
34.9 mb)
Manifold Pressure: 5” water column (12.5 mb) 
Propane Gas Requirements: 
Inlet Connection: 1/2” NPT (min. 3/4” dia. flex line)
Supply Pressure: 11” min. to 14” max. water column (27.4 
mb to 34.9 mb)
Manifold Pressure: 10” water column (24.9 mb) 
WARNING
 
If a gas conversion kit is used, the kit shall be 
installed by a qualified service agency in 
accordance with the manufacturer’s instructions 
and all applicable codes and requirements of 
the authority having jurisdiction. If the 
information in the instructions is not followed 
exactly, a fire, explosion or production of carbon 
monoxide may result causing property damage, 
personal injury or loss of life. The qualified 
service agency is responsible for the proper 
installation of the kit. The installation is not 
proper and complete until the operation of the 
converted appliance is checked as specified in 
the manufacturer’s instructions supplied with the 
kit. 
Hook Up 
A manual gas shut-off valve must be installed external 
to the appliance, in a location accessible from the front, 
for the purpose of shutting off the gas supply. The 
supply line must not interfere with the back of the unit. 
Make sure the gas supply is turned off at the manual 
shut-off valve before connecting the appliance. 
The installer should inform the consumer of the 
location of the gas shut-off valve. Make sure all users 
know where and how to shut off the gas supply to the 
cooktop. 
The gas supply connections shall be made by a 
competent technician and in accordance with local 
codes or ordinances. In the absence of local codes, the 
installation must conform to the National Fuel Gas 
Code ANSI Z223.1/NFPA54-current issue. 
Always use pipe-sealing compound or Teflon® tape on 
the pipe threads, and be careful not to apply excessive 
pressure when tightening the fittings. 
Leak testing of the appliance shall be in accordance 
with the following instructions. 
Turn on gas and check supply line connections for 
leaks using a soap and water solution. 
Bubbles forming indicate a gas leak. Repair all 
leaks immediately after finding them. 
WARNING
Do not use a flame of any kind to check for gas 
leaks. 
All installer-supplied parts must conform to 
applicable codes. 
CAUTION 
When connecting unit to propane gas, make 
certain the propane gas tank is equipped with its 
own high pressure regulator in addition to the 
pressure regulator supplied with the appliance. 
The pressure of the gas supplied to the 
appliance regulator must not exceed a 14” water 
column (34.9 mb).
CAUTION 
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut-off valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psig 
(3.5kPa).
The appliance and its individual shut off valve 
must be disconnected from the gas supply 
piping system during any pressure testing of the 
system at test pressures in excess of 1/2 psig 
(3.5kPa.).
When checking the manifold gas pressure, the 
inlet pressure to the regulator should be at least 
6.0" W.C. for natural gas or 11.0" for propane.
Do not attempt any adjustment of the pressure 