WHEN FLAME IS PROPERLY ADJUSTED: 
There should be a flame at each burner port. 
There should be no air gap between the flame and 
burner port. 
 
Call Thermador if: 
1. Any of the burners do not light. 
2. Any of the burners continue to burn yellow. 
Installer Checklist
Final Check List 
Cooktop correctly positioned in countertop recess. 
Specified clearances maintained to cabinet surfaces. 
Burner caps positioned properly on burner bases. 
All packaging material removed.
Island Trim or Backguard attached according to 
instructions. 
Gas Supply
Connection: 1/2" NPT with a minimum 3/4" diameter 
flex line. 
If converting from natural to LP gas, refer to LP 
Conversion Instructions for details. 
Manual gas shut off valve installed in an accessible 
location (without requiring removal of appliance). 
Unit tested and free of gas leaks. 
Electrical 
For models with the electric griddle, a polarized and 
grounded 120VAC receptacle with 15 AMP over 
current protection is provided for service cord 
connection. 
Operation 
All internal packing materials removed. (Check below 
grates and grill pans.) 
Bezels centered on burner knobs, and knobs turn 
freely. 
Purge air from gas system by operating one of the top 
burners for several minutes. 
Each burner lights satisfactorily, both individually and 
with other burners operating. 
Burner grates are correctly positioned. 
Installer
Give CARE and USE MANUAL and INSTALLATION 
INSTRUCTIONS to your customer. 
 Figure 12: Flame Characteristics
If the flame is completely or mostly yellow, verify that the 
regulator is set for the correct fuel. After adjustment, 
retest.
Some orange-colored streaking is normal during the 
initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate before 
making adjustments.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.