Force10 S25N/S50N power supply shelf, holds 8 redundant PSU SA-01-EPS Folheto

Códigos do produto
SA-01-EPS
Página de 2
© 2009 Force10 Networks, Inc. All rights reserved. Force10 Networks, Adit, 
E-Series, Traverse, and TraverseEdge are registered trademarks and Axxius,
C-Series, ExaScale, FTOS, MASTERseries, P-Series, S-Series, TeraScale, and
TransAccess are trademarks of Force10 Networks, Inc. All other company names
are trademarks of their respective holders. Information in this document is subject
to change without notice. Certain features may not yet be generally available.
Force10 Networks, Inc. assumes no responsibility for any errors that may appear 
in this document.
SSDS04
609   v3.56
Force10 Networks, Inc.
350 Holger Way
San Jose, CA 95134 USA
www.force10networks.com
408-571-3500
PHONE
408-571-3550
FACSIMILE
Physical
S25N: 24 line-rate 10/100/1000Base-T ports
S50N: 48 line-rate 10/100/1000Base-T ports
4 SFP ports (shared)
1 RJ45 console/management port with RS232 signaling
Optional modules:
2 line-rate ports 10 Gigabit Ethernet XFP 
2 line-rate ports 10 Gigabit Ethernet CX4
2 line-rate ports 12 Gigabit Stacking
1 line-rate port 24 Gigabit Stacking
Size: 1 RU, 1.7 h x 17.32 w x 16.73" d (4.3 h x 44 w x 42.5 cm d)
Weight: 14.39 lbs (6.54 kg)
ISO 7779 A-weighted sound pressure level: 
S25N: 42.0 dBA at 73.4°F (23°C), S50N: 59.6 dBA at 73.4°F (23°C)
Power supply: 100–240 VAC 50/60 Hz, –44 to -60 VDC
Max. thermal output: S25N: 349 BTU/h
S50N (AC): 531 BTU/h, S50N (DC): 465 BTU/h
Max. current draw per system: 
2 A at 100/120 VAC, 1 A at 200/240 VAC, 3.6 A at -48 VDC
Max. power consumption: S25N: 102 W
S50N (AC): 156 W, S50N (DC): 136 W
Max. operating specifications:
Operating temperature: 32° to 122°F (0° to 50°C)
Operating humidity: 10 to 85% (RH), non-condensing
Max. non-operating specifications:
Storage temperature: –40° to 158°F (–40° to 70°C)
Storage humidity: 5 to 95% (RH), non-condensing
Reliability: S25N: MTBF 141,275 hours, S50N (AC): MTBF 169,315 
hours, S50N (DC): MTBF 168,259 hours
Redundancy
Ring stacking topology with dynamic master election
Dual modular slots with up to four 10 GbE ports
Link aggregation across stack members
Power redundancy
Performance
MAC addresses:
S25N: 16K, S50N: 32K
IPv4 routes: 
4K
IPv6 routes: 
2,500
Switching fabric capacity:
S25N: 144 Gbps, S50N: 288 Gbps
User traffic capacity:
S25N: 128 Gbps (95 Mpps)
S50N: 176 Gbps (131 Mpps)
Link aggregation:
8 links per group, 128 groups per stack
Stacking capacity:
96 Gbps per stack member
Queues per port:
4 queues
VLANs:
1024 VLANs with 4096 tag value support
Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
Line-rate Layer 3 routing:
IPv4 and IPv6
LAG load balancing: 
based on Layer 2, IPv4 or IPv6 headers
Switching latency: 
<5 µs for 64 byte frames
IEEE Compliance
802.1AB LLDP
802.1D
Bridging, STP
802.1p
L2 Prioritization
802.1Q
VLAN Tagging, Double VLAN Tagging, GVRP
802.1s
MSTP
802.1w
RSTP
802.1X
Network Access Control
802.3ab
Gigabit Ethernet (1000BASE-T)
802.3ac
Frame Extensions for VLAN Tagging
802.3ad
Link Aggregation with LACP
802.3ae
10 Gigabit Ethernet (10GBASE-X)
802.3ak
10 Gigabit Ethernet (10GBASE-CX4)
802.3i
Ethernet (10BASE-T)
802.3u
Fast Ethernet (100BASE-TX)
802.3x
Flow Control
802.3z
Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057      LLDP-MED
Force10
FRRP (Force10 Redundant Ring Protocol)
Force10
PVST+
MTU
9,252 bytes
RFC and I-D Compliance
General Internet Protocols
768
UDP
793
TCP
854
Telnet
959
FTP
General IPv4 Protocols
791
IPv4
792
ICMP
826
ARP
1027
Proxy ARP
1035
DNS (client)
1042
Ethernet Transmission
1191
Path MTU Discovery
1305
NTPv3
1519
CIDR
1542
BOOTP (relay)
General IPv6 Protocols
1981
Path MTU Discovery
(partial)
2460
IPv6
2461
Neighbor Discovery 
(partial)
2462
Stateless Address 
Autoconfiguration 
(partial)
RIP
1058
RIPv1
OSPF
2154
MD5
1587
NSSA
2328
OSPFv2
2370
Opaque LSA
BGP
1997
Communities
2385
MD5
2439
Route Flap Damping
2796
Route Reflection
2842
Capabilities
2858
Multiprotocol Extensions
draft-ietf-idr-bgp4-20    BGPv4
draft-ietf-idr-restart-06    Graceful Restart
Multicast
1112
IGMPv1
2236
IGMPv2
3376
IGMPv3
draft-ietf-pim-sm-v2-new-05    PIM-SM
Network Management
1155
SMIv1
1156
Internet MIB
1157
SNMPv1
1212
Concise MIB Definitions
1215
SNMP Traps
1493
Bridges MIB
1850
OSPFv2 MIB
1901
Community-based SNMPv2
2011
IP MIB
2012
TCP MIB
2013
UDP MIB
2024
DLSw MIB
2096
IP Forwarding Table MIB
2570
SNMPv3
2571
Management Frameworks
2572
Message Processing and Dispatching
2574
SNMPv3 USM
2575
SNMPv3 VACM
2576
Coexistence Between SNMPv1/v2/v3
2578
SMIv2
2579
Textual Conventions for SMIv2
2580
Conformance Statements for SMIv2
2618
RADIUS Authentication MIB
2665
Ethernet-like Interfaces MIB
2674
Extended Bridge MIB
2787
VRRP MIB
2819
RMON MIB (groups 1, 2, 3, 9)
2863
Interfaces MIB
2865
RADIUS
3273
RMON High Capacity MIB
3416
SNMPv2
3418
SNMP MIB
3434
RMON High Capacity Alarm MIB
3580
802.1X with RADIUS
5060
PIM MIB
ANSI/TIA-1057
LLDP-MED MIB
draft-grant-tacacs-02
TACACS+
draft-ietf-idr-bgp4-mib-06 BGP MIBv1
IEEE 802.1AB
LLDP MIB
IEEE 802.1AB
LLDP DOT1 MIB
IEEE 802.1AB
LLDP DOT3 MIB
ruzin-mstp-mib-02
MSTP MIB (traps)
sFlow.org
sFlowv5
sFlow.org
sFlowv5 MIB (version 1.3)
FORCE10-BGP4-V2-MIB Force10 BGP MIB
(draft-ietf-idr-bgp4-mibv2-05)
FORCE10-IF-EXTENSION-MIB
FORCE10-LINKAGG-MIB
FORCE10-COPY-CONFIG-MIB
FORCE10-MON-MIB
FORCE10-PRODUCTS-MIB
FORCE10-SS-CHASSIS-MIB
FORCE10-SMI
FORCE10-SYSTEM-COMPONENT-MIB
FORCE10-TC-MIB
FORCE10-TRAP-ALARM-MIB
Regulatory Compliance
Safety
UL/CSA 60950-1, 1st Edition
EN 60950-1, 1st Edition
IEC 60950-1, 1st Edition Including all National Deviations 
and Group Differences
EN 60825-1 Safety of Laser Products Part 1: Equipment 
Classification Requirements and User's Guide
EN 60825-2 Safety of Laser Products Part 2: Safety of 
Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Emissions
Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022: 2006 (CISPR 22: 2006), Class A
Japan: VCCI V3/2007.04 Class A
USA: FCC CFR 47 Part 15, Subpart B, Class A
Immunity
EN 300 386 V1.3.3: 2005 EMC for Network Equipment
EN 55024: 1998 + A1: 2001 + A2: 2003
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
RoHS
All S-Series components are EU RoHS compliant.
The features and specifications are for FTOS. For SFTOS features
and specifications, please refer to the SFTOS data sheet.
Ordering Information
O
RDER
N
UMBER
D
ESCRIPTION
S25-01-GE-24T
24-port 10/100/1000Base-T chassis
with 4 SFP ports, 2 modular slots,  
2 AC power supplies, FTOS software
S50-01-GE-48T-AC-2 48-port 10/100/1000Base-T chassis with 
4 SFP ports, 2 modular slots, 1AC + 1 DC
power supply, FTOS software
S50-01-GE-48T-DC-2 48-port 10/100/1000Base-T chassis 
with 4 SFP ports, 2 modular slots,  
2 DC power supplies, FTOS software
S50-01-10GE-2P 
2-port 10 GbE XFP module
S50-01-10GE-2C 
2-port 10 GbE CX4 module
S50-01-12G-2S 
2-port 12 Gbps stacking module
S50-01-24G-1S 
1-port 24 Gbps stacking module
S50-01-SSC-12G 
60 cm stacking cable for S50-01-12G-2S
S50-01-LSC-12G 
4 m stacking cable for S50-01-12G-2S
S50-01-SSC-24G 
60 cm stacking cable for S50-01-24G-1S
S50-01-LSC-24G 
4 m stacking cable for S50-01-24G-1S
SA-01-PSU 
S25N/S50N redundant power supply unit
SA-01-EPS 
S25N/S50N power supply shelf, holds 
eight redundant power supply units
SW-SB-LATEST 
Layer 3 FTOS software upgrade
Specifications: 
S-Series Data Center Switches
1321
MD5
1350
TFTP
2474
Differentiated Services
3164
Syslog
1812
Routers
1858
IP Fragment Filtering
2131
DHCP (server and relay)
2338
VRRP
3021
31-bit Prefixes
3046
DHCP Option 82
3069
Private VLAN
3128
Tiny Fragment Attack 
Protection
2463
ICMPv6
2464
Ethernet Transmission
2675
Jumbograms
3587
Global Unicast 
Address Format
4291
Addressing
2453
RIPv2
3623
Graceful Restart
4222
Prioritization and 
Congestion Avoidance
2918
Route Refresh
3065
Confederations
4360
Extended Communities
4893
4-byte ASN
5396
4-byte ASN 
Representation
3569
SSM for IPv4
4541
IGMPv1/v2 Snooping