Hoshizaki 73183 Manual Do Utilizador

Página de 42
40
B. Important Notes for Component Replacement
CAUTION
When replacing a component listed below, see the notes to help ensure proper 
operation.
Component
Notes
Compressor
Install a new start relay, start capacitor, and compressor overload (compressor overload 
is integrated with the start relay on refrigerators; internal on 1-section freezers; external on 
2-section freezers). 
Compressor, 
Evaporator 
Fan Motor, 
Condenser Fan 
Motor
WARNING! To reduce the risk of electric shock, be sure to reconnect the 
component's ground wire.
Expansion Valve • Attach the expansion valve bulb to the suction line in the same location as the previous
bulb. 
• Secure the bulb with the clamp and holder, then insulate it.
Defrost 
Thermistor
After working with or around the defrost thermistor on a freezer, make sure the defrost 
thermistor wire is not touching the defrost heater.
Control Module
 If three dashes (- - -) appear on the display module when energized, the compressor and 
display module are off. To turn the compressor and display module on, press and hold 
the upper and lower buttons until the temperature appears on the display. 
CAUTION! The 
three dashes must be cleared, otherwise the compressor will not run and product 
will be lost.
C. Door Re-Hinging
This unit is provided with a cabinet design which, after being delivered to the installation 
location, permits changing of the door swing from left to right or right to left. To change 
the door swing, an HS kit from your local Hoshizaki distributor is required. See the table 
below. 
CAUTION! Improper installation of the HS kit may result in the doors not 
closing completely and/or the gaskets not sealing correctly. For further details, 
contact your local Hoshizaki distributor or Hoshizaki Technical Support at  
1-800-233-1940.
Convert
HS Kit Number
Right Hinge to Left Hinge
HS-3725
Left Hinge to Right Hinge
HS-3726