(2) Connection to a Closed Loop System
Condenser Water 
Supply Inlet 
Minimum Condenser 
Water Supply Line Size 
Condenser 
Return Outlet
Minimum Condenser 
Return Line Size
1/2" Female Pipe 
Thread (FPT)
1/4" Nominal ID Copper 
Water Tubing or Equivalent
3/8" Female Pipe 
Thread (FPT)
1/4" Nominal ID Copper 
Water Tubing or Equivalent
• Shut-off valves and drain valves must be installed at both the condenser water supply inlet 
and condenser return outlet.
• Minimum water flow to the condenser is 4 GPM. 
• The pressure differential between the condenser water supply inlet and condenser return 
outlet must be no less than 10 PSIG.
• When using a glycol blend, the solution mixture should be less than 30% glycol.
• In order to maintain the proper high side pressure, the condenser water supply inlet 
temperature should not drop below 45°F (7°C) and the condenser return outlet 
temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker 
installation is complete, confirm the condenser return outlet temperature 5 minutes after a 
freeze cycle starts. If the condenser return outlet temperature is not in the proper range, 
use a flat blade screwdriver to rotate the adjustment screw on the water-regulating valve 
until the temperature is in the proper range (rotate counterclockwise to raise temperature 
or clockwise to lower temperature).
Fig. 6
Water-Cooled Models
Connection to a Closed Loop System
Model Shown: 
KML-451MWH
Icemaker
Icemaker Water 
Supply Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
2-inch (5-cm) air gap
Floor Drain
Icemaker
Drain Outlet 
3/4" FPT
Vent Tube
Vent Tube
Condenser Water 
Supply Inlet
1/2" FPT
Condenser 
Return Outlet 
3/8" FPT
Shut-Off Valve
Minimum 1/4" Nominal ID Copper 
Water Tubing or Equivalent
Drain Valve
Ice 
Storage 
Bin
Minimum 3/4" Nominal ID 
Hard Pipe or Equivalent
Separate piping to approved 
drain. Leave a 2-inch (5-cm) 
vertical air gap between the 
end of each pipe and the 
drain.
Be sure there is sufficient 
extra water supply line and 
drain line for the appliance 
to be pulled out for service.