Hoshizaki KML-250MAH Manual Do Utilizador

Página de 40
6
I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label 
can be seen by removing the front panel. The nameplate is located on the rear panel. For 
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KML-250M_H
Model Number
KML-250AH
KML-250MWH
AC Supply Voltage
115/60/1
115/60/1
Compressor
115V 7.0RLA 33.6LRA
115V 6.7RLA 33.6LRA
Pump
120V 0.5FLA 23W
120V 0.5FLA 23W
Fan
115V 1.2FLA 25W
--- --- ---
Other
115-120V 0.2A
115-120V 0.2A
Maximum Fuse Size 20 AMPS
20 AMPS
Max. HACR Breaker 
(USA Only)
20 AMPS
20 AMPS
Max. Circuit Breaker 
(Canada Only)
20 AMPS
20 AMPS
Minimum Circuit 
Ampacity
20 AMPS
20 AMPS
Design Pressure
HI-467PSI LO-230PSI
HI-427PSI LO-230PSI
Refrigerant
404A 1 LB. 2 OZ.
404A 14.1 OZ.
2. KML-351M_H
Model Number
KML-351MAH
KML-351MWH
AC Supply Voltage
115/60/1
115/60/1
Compressor
115V 6.1RLA 50LRA
115V 6.7RLA 33.6LRA
Pump
120V 0.5FLA 23W
120V 0.5FLA 23W
Fan
115V 0.85FLA 50W
--- --- ---
Other
115-120V 0.2A
115-120V 0.2A
Maximum Fuse Size 20 AMPS
20 AMPS
Max. HACR Breaker 
(USA Only)
20 AMPS
20 AMPS
Max. Circuit Breaker 
(Canada Only)
20 AMPS
20 AMPS
Minimum Circuit 
Ampacity
20 AMPS
20 AMPS
Design Pressure
HI-467PSI LO-230PSI
HI-427PSI LO-230PSI
Refrigerant
404A 1 LB. 9.4 OZ.
404A 1 LB. 1.6 OZ.