Hoshizaki MWH KML-351MAH Manual Do Utilizador

Página de 40
19
1. Icemaker
Icemaker Water 
Supply Inlet 
Minimum Icemaker 
Water Supply Line Size 
Icemaker Drain 
Outlet
Minimum Icemaker 
Drain Line Size
1/2" Female Pipe 
Thread (FPT)
1/4" Nominal ID 
Copper Water Tubing or 
Equivalent
3/4" Female Pipe 
Thread (FPT)
3/4" Nominal 
ID Hard Pipe or 
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be 
pulled out for service.
Fig. 4
Model Shown: 
KML-631MRH
Air-Cooled and Remote Models
Remote Condenser 
Line Set Connections
(Remote Model)
Shut-Off Valve
Drain Valve
Icemaker
Icemaker Water 
Supply Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
2-inch (5-cm) air gap
Floor Drain
Icemaker
Drain Outlet 
3/4" FPT
Minimum 1/4" Nominal ID Copper 
Water Tubing or Equivalent
Vent Tube
Minimum 3/4" Nominal ID 
Hard Pipe or Equivalent
Ice 
Storage 
Bin
Separate piping to approved 
drain. Leave a 2-inch (5-cm) 
vertical air gap between the 
end of each pipe and the 
drain.
Be sure there is sufficient 
extra water supply line and 
drain line for the appliance 
to be pulled out for service.