Broan GSFH1K Manual Do Utilizador

Página de 14
2.3 O
PERATING
40425 C
ONTROLLER
The included wall control 40425 is intented for GSHH3K and GSEH3K units only.
The wall control is in OFF mode when power is applied for the first time. The mode
does not change following a power failure.
2. CONTROLS 
(CONT’D)
- 6 -
VC0098
I
LLUMINATES IN
ALL MODES
EXCEPT
OFF
MODE
.
• P
RESS EITHER
BUTTON TO CHANGE
CONFIGURATION SETTING
(
SEE SECTION
2.3.3).
• P
RESS BOTH
BUTTONS TO RESET
THE FILTER COUNTER OR
PREFILTER COUNTER
.
P
RESS THIS BUTTON TO
SWITCH MODE
(
SEE
S
ECTION
2.3.2).
F
ILTER AND PREFILTER
MAINTENANCE
LED.
F
LASHES WHEN IT IS
TIME TO REPLACE
PREFILTER AND WASH
CORE FILTERS
.
S
EE
S
EMI
-A
NNUAL
M
AINTENANCE IN
S
ECTION
3.1.
L
IGHTS UP WHEN IT IS
TIME TO REPLACE FILTER
AND PREFILTER AND
WASH CORE FILTERS
.
S
EE
A
NNUAL
M
AINTENANCE
S
ECTION
3.2.
P
RESS THIS BUTTON TO
ACCESS CONFIGURATION
PARAMETERS
(
SEE
S
ECTION
2.3.3).
40425
2.3.2 U
SING
40425 C
ONTROLLER
The wall controller 40425 provides 5 operation modes. Press the Mode button to
select the desired mode.
The unit exchanges air 
at normal speed. 
The outdoor 
temperature* is displayed.
The unit exchanges air 
at high speed. 
The outdoor 
temperature* is displayed.
N
ORMAL
M
ODE
(M
IN
)
B
OOST
M
ODE
(M
AX
)
2.3.1 40425 C
ONTROLLER
D
ESCRIPTION
* The outdoor temperature reading is taken from the unit 
FRESH AIR FROM  
OUTSIDE  port; due to the lenght of the insulated duct, the reading is slightly 
different from the real outside temperature.