KitchenAid KICU265H Folheto
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
KICU265H
KICU285H
KICU285H
Electrical:
120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
delay fuse or circuit breaker and separate circuit is
recommended.
36" and 48" Island Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Instructions packed with product. Specifications subject to change without notice.
Ref. 4360369 Rev. C
10-15-02
®
8’ (2.4 m) min. -
9’ (2.7 m) max.
ceiling to floor
9’ (2.7 m) max.
ceiling to floor
support
structure
structure
24" (61 cm) min.
bottom of canopy to
cooking surface
bottom of canopy to
cooking surface
canopy
lower
chimney
chimney
upper
chimney
chimney
36" (91.4 cm)
base cabinet
height
base cabinet
height
3-1/4" x 10"
(8.3 cm x 25 cm)
through
the roof
(8.3 cm x 25 cm)
through
the roof
roof cap
Horizontal wall venting
3-1/4" x 10"
(8.3 cm x 25 cm)
through the wall
(8.3 cm x 25 cm)
through the wall
wall cap
Vertical roof venting
The vent system length should not
exceed the lengths shown in the
chart below.
exceed the lengths shown in the
chart below.
Vent size
Maximum length
3-1/4" x 10"
35 ft. (10.7 m)
(8.3 cm x 25 cm)
7" (17.8 cm) round
40 ft. (12.2 m)
8" (20.3 cm) round
50 ft. (15.2 m)
9" (22.9 cm) round
60 ft. (18.3 m)
Vent Piece
3-1/4" x 10" (8.3 cm x 25 cm) 7" (17.8 cm), 8" (20.3 cm)
Rectangular
or 9" (22.9 cm) Round
45° elbow
7.0 feet
2.5 feet
(2.1 m)
(0.8 cm)
90° elbow
5.0 feet
5.0 feet
(1.5 m)
(1.5 m)
90° flat elbow
12.0 feet
(3.7 m)
transition to round
5.0 feet
(1.5 m)
wall cap
0.0 feet
(0.0 m)
3-1/4" x 10”
(8.3 cm x 25 cm)
elbow
(8.3 cm x 25 cm)
elbow
wall
cap
cap
Maximum length
= 35 ft. (10.7 m)
1 — 90° elbow
= 5 ft. (1.5 m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 — wall cap
1 — wall cap
= 0 ft. (0 m)
Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system
(8.3 cm x 25 cm)
system
= 13 ft. (4 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
3-1/4" x 10" (8.3 cm x 25 cm)
vent system
To calculate the length of the system you need, add the
equivalent feet for each vent piece used in the system.
equivalent feet for each vent piece used in the system.
Note: Flexible vent is Not
recommended.
recommended.
If it is used, each foot of flexible vent
used is equivalent to two feet (61 cm)
of straight metal vent when
calculating the vent system length.
(Example: A flexible elbow equals two
standard elbows.)
used is equivalent to two feet (61 cm)
of straight metal vent when
calculating the vent system length.
(Example: A flexible elbow equals two
standard elbows.)
36" hood 35-3/8" (89.9 cm) or
48" hood 47-1/4" (120 cm)
overall width
48" hood 47-1/4" (120 cm)
overall width
23-5/8" (60 cm)
overall depth
overall depth
24-5/8" (62.5 cm) min. -
34-3/4" (88.3 cm) max.
overall chimney height
34-3/4" (88.3 cm) max.
overall chimney height
23-5/8"
(60 cm)
lower
chimney
height
(60 cm)
lower
chimney
height
1" (2.5 cm) min. -
11-1/8" (23.8 cm) max.
upper chimney height
11-1/8" (23.8 cm) max.
upper chimney height
10-1/4" (26 cm)
canopy height
canopy height
7 1/16"
(17.9 cm)
10 7/8"
(27.6 cm)
Note: 3-1/4" x 10"
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.
Note: 3-1/4" x 10"
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.