Air King AK110PN Folheto

Página de 1
CUL/HVI
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
7
7/8
"
4"
10
7/8
"
9
3/8
"
11"
13
3/4
"
SPECIFICATIONS
EXHAUST FANS
AK110PN
100 CFM/1.5 SONES @ 0.10" wg. • 90 CFM/1.5 SONES @ 0.25 wg.
HVI CERTIFIED 120 Volts, 0.31 amps, 60 hz.
• Grill
White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 11" x 13
3/4
".
• Blower Wheel
Balanced polymeric dual inlet blower wheel 5
13/32
"  dia. x 4"
depth, 30 paddles, secured in place using 8M hex nut.
• Motor
Enclosed 4 pole electronically balanced permanently split
capacitor motor (PSC); life time lubricated. Motor bearings -
ball. Suitable for continuous operation. Rated 115/120 volts, 60
Hz, 0.31 amps.
• Fan Housing
23 gauge galvanized steel housing, fully sealed.
Overall dimensions 10
7/8
" x 9
3/8
" x 7
7/8
".
• Duct Collar
4" round, zinc plated metal collar adapter. 4" spring loaded
aluminum backdraft damper.
• Ventilating Area
For bathrooms up to 100 sq. ft. For other rooms up to 125 sq. ft.
• Electrical Connections
1/2
" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania  19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048
Updated 6-06
Specifications subject to change without notice.
• Unit Mounting
The housing will mount in ceilings with  at least 8" of clearance
and through drywall thickness up to 
3/4
", with a rough-in opening
of 11
1/8
" x 9
5/8
". Rated for ceilings insulated to R-40. The housing
will mount either between 16" or 24" on center joists, using the
4 supplied housing mounting rails. The housing mounting rails
can be adapted for overhead mounting (hardware not provided).
• Single Pack Shipping Info
Box Dim: 14
1/8
" x 11
5/8
" x 9
5/8
"
UPC: 0-8316221012-7
Shipping Weight: 11.5 lbs.
C
US
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN
MODEL
CFM
IN
RPM
WATTS
AMPS
SONES
QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER
W.G.
& REMARKS
PERFORMANCE
HVI Sones
Fan Speed
Power
Static Pressure (inches of w.g.)
@ .1 SP
RPM
Watts
0
0.05
0.1
0.125
0.15
0.2
0.25
0.3
Air Flow - CFM
104
102
100
99
98
95
90
71
1.5
1106
29