S2 Dip Switch Setting
Anti-Slush Control
No. 5
No. 6
OFF
OFF
Activated (Ver. 1.0)
ON
OFF
Activated (Ver. 2.0)
OFF
ON
Deactivated
ON
ON
Deactivated
Control Board P01771-02
j) Harvest Promotion Control (S2 dip switch 2) [Program Ver. 3.2]
Do not adjust. This must be left in the factory default position or the unit will not operate 
properly.
When activated, this control promotes harvest of ice on the evaporator that is hard to 
remove. If the harvest cycle exceeds 6 minutes, the pump motor starts to operate for a 
maximum of 3 minutes.
S2 Dip Switch Setting
Harvest Promotion 
Control
No. 2
OFF
Activated
ON
Deactivated
k) Refi ll Counter (S2 dip switch 3) [Program Ver. 3.2]
Do not adjust. This must be left in the factory default position or the unit will not operate 
properly. The KM-201BAH/BWH and KM-260BAH/BWH do not refi ll.
l) Harvest Completion Detection Control (S2 dip switch 4) [Program Ver. 3.2]
Do not adjust. This must be left in the factory default position or the unit will not operate 
properly.
It is deactivated on the KM-201BAH/BWH and KM-260BAH/BWH.
When activated, this control determines whether ice remains on the evaporator at the 
end of a harvest cycle and at the beginning of a freeze cycle. If ice drops and activates 
the bin control switch in the last 10 seconds of a harvest cycle, the control determines 
that ice still remains on the evaporator and extends the harvest cycle for 30 seconds. 
If the bin control switch is activated at the beginning of a freeze cycle, the control 
determines that ice still remains on the evaporator and starts a harvest cycle after the 
minimum freeze cycle time has passed.
S2 Dip Switch Setting
Harvest Completion 
Detection Control
No. 4
OFF
Deactivated
ON
Activated