Beckett SL4100 Manual Do Utilizador
4
Ratings and Data
Boiler
Model
No.
SL375 SLD375 SL4100 SLD4100 SL5125 SLD5125 SL6150 SL7175
Firing Rate - #2 Fuel
0.75
0.75
1.00
1.00
1.25
1.25
1.50
1.75
Input
BTU/HR
105,000 105,000 140,000
140,000
175,000
175,000 210,000
245,000
DOE
Capacity
BTU/HR
91,000 91,000 122,000
122,000
153,000
153,000 184,000
208,250
Net IBR Rating BTU/HR
79,000
79,000
106,000
106,000
133,000
133,000
160,000
181,100
Net Rating Sq. Ft.
526
526
707
707
887
887
1,067
1,207
AFUE
Rating
85.5 85.5 86.5
86.5
86.9
86.9 86.9
85.0
Water
Capacity
3.6 3.6 4.3
4.3
5.1
5.1 5.8
6.5
Approx. Shipping Weight
300
300
350
350
390
390
430
470
Cabinet Height
28 7/8"
28 7/8"
28 7/8"
28 7/8"
28 7/8"
28 7/8"
28 7/8"
Cabinet Width
17 3/4"
17 3/4"
17 3/4"
17 3/4"
17 3/4"
17 3/4"
17 3/4"
Cabinet Length
19 1/4"
19 1/4"
22 3/4"
22 3/4"
26 1/4"
29 3/4"
33 1/4"
Supply Outlet Height C.L.
25 3/8"
25 3/8"
25 3/8"
25 3/8"
25 3/8"
25 3/8"
25 3/8"
Return Outlet Height C.L.
4 1/2"
4 1/2"
4 1/2"
4 1/2"
4 1/2"
4 1/2"
4 1/2"
Flue
Outlet
Diameter 6" 6" 6" 6" 6" 6" 6"
Flue Outlet Height C.L.
20 3/4"
20 3/4"
20 3/4"
20 3/4"
20 3/4"
20 3/4"
20 3/4"