Element Conditions 
Relay drive requirements are defined as a percentage of on time based on a 60 second cycle. 
 
Bake .......................First rise to temperature = 100% bake, 50% broil, then 100% bake, 25% broil 
Broil........................100% broil, 0% bake 
Clean ......................100% broil, 25% bake 
Convection ............First rise to temperature = 100% bake, 50% broil, then 100% Convection element 
 
For convection bake or convection broil refer to bake and broil specifications 
Continuity is indicated as 100
Ω
 and below. Each pad must be pressed to perform the following test. 
 
J1 - 2
J1 - 20
J1 - 1
J1 - 6
J1 - 7
J1 - 5
J1 - 4
J1 - 3
J1-
14
J1-
13
J1-
12
J1-
11
J1-
10
J1-
9
J1-
8
J1-
16
J1-
18
J1-
19
BAKE BROIL
TIMER CLOCK
CLEAN
STOP
TIME
OVEN
LIGHT
CANCEL
SLEW
DOWN
SLEW
  UP
COOK
TIME
Switch Matrix for AOES3030
 
 
 
J1 - 2
J1 - 20
J1 - 1
J1 - 6
J1 - 7
J1 - 5
J1 - 4
J1 - 3
J1
-1
4
J1
-1
3
J1
-1
2
J1
-1
1
J1
-1
0
J1
-9
J1
-8
J1
-1
6
J1
-1
8
J1
-1
9
BAKE
    1
BROIL
    1
TIMER CLOCK
CLEAN
    1
CONV
    1
CONV
BAKE
1
CONV
BROIL
1
STOP
TIME
OVEN
LIGHT
PANEL
LIGHT
CANCEL
      1
SLEW
DOWN
SLEW
  UP
COOK
TIME
1
Switch Matrix for AOCS3040
 
 
Control
 Panel
Ribbon Cable
Pin 1 is located at the 
bottom of the connector.
Top
Bottom