Middleby Marshall Model PS536 Manual Do Utilizador

Página de 84
5
ENGLISH
Table 1-3:  Electrical specifications for electric ovens (per oven cavity)
Main  Blower
Control
Current  Draw
k W
  Voltage
Circuit  Voltage
Phase
Freq.
L1
L2
L3
N
Rating
Poles
Wires
208V
120V  conv.  speed  control,
3 Ph
60 Hz
50A 50A 50A
--
16.0 kW
4 Pole
4 Wire
drive  motor,  contactor,
at  208V
(3 hot, 1 gnd)
&  temp.  control;  all  others  208V
230V
120V  conv.  speed  control,
3 Ph
60 Hz
45A 45A 45A
--
16.0 kW
4 Pole
4 Wire
drive  motor,  contactor,
at  230V
(3 hot, 1 gnd)
&  temp.  control;  all  others  230V
380V  *
120V  conv.  speed  control,
3 Ph
50 Hz
25A 25A 28A 5A
16.0 kW
4 Pole
5 Wire (3 hot,
drive  motor,  contactor,
at  380V
1 neutral, 1 gnd)
&  temp.  control;  380V  heating
elements;  all  others  240V
*  380V model is not approved by 
 or 
 .
SECTION 1 - DESCRIPTION
Table 1-5:  Gas orifice and pressure specifications (per oven cavity)
Orifice  (Manifold)
Gas  Type
Main  Orifice  I.D.
Pilot  Orifice  I.D.
Supply  (Inlet)  Pressure
Pressure
Natural
0.0935” (2.3749mm, #42 drill)
0.018” (0.46mm)
4-7” W.C. (9.95-17.4mbar) *
3.5” W.C. (8.7mbar)
Propane
0.0520” (1.3208mm, #55 drill)
0.018” (0.46mm)
11-14” W.C. (27.4-34.9mbar) *
10.5” W.C. (24.9mbar)
The  gas  supply  pressures  shown  are  for  ovens  installed  in  North  America.    The  required  gas  supply  pressures  of  other  locations  are
dependent on the local gas type and on all applicable local codes.
Table 1-4:  Electrical specifications for gas ovens (per oven cavity)
Main  Blower
Control
Current
  Voltage
Circuit  Voltage
Phase
Freq.
Draw
Poles
Wires
208/240V
120V  conv.  speed  control,
1 Ph
60 Hz
6A
3 Pole
4 Wire (2 hot, 1 neut, 1 gnd)
drive  motor,  contactor,
&  temp.  control;  all  others
as  per  line  (208/240V)
IMPORTANT
Additional electrical information is provided on the oven's serial plate, and on the wiring diagram inside the machinery
compartment.