Classification:
"Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Designation:
ANSI / NEDA-5011LC, IEC-CR2425
Nominal Voltage:
3.0 Volts
Typical Capacity:
290 mAh (to 2.0 volts)
(Rated at 10K ohms at 21°C)
Typical Weight:
4.6 grams (0.16 oz.)
Typical Volume:
1.3 cubic centimeters (0.08 cubic inch)
Max Rev Charge:
1 microampere
Energy Density:
183 milliwatt hr/g, 647 milliwatt hr/cc
Typical Li Content:
0.21 grams (0.0074 oz.)
UL Listed:
MH12454
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Load
Cutoff
2.0V
(ohms)
(hours)
10,000
1,000
Bkgnd Drain: Continuous
10K ohms
0.29 mA @2.9V
Pulse Drain: 2 seconds X 12 times/day
300 ohms
9.3 mA @2.7V
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Typical Drains:
at 2.9V 
(mA)
0.29
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication. 
Continuous
Schedule:
(2) Battery compartment design. To prevent children from removing 
batteries, battery compartments should be designed with one of the 
following methods: a) a tool such as screwdriver or coin is required to 
open battery compartment or b) the battery compartment door/cover 
requires the application of a minimum of two independent and 
simultaneous movements of the securing mechanism to open by hand. 
Screws should remain captive with the battery door or cover.
Industry Standard Dimensions
Global (except US):
United States:
ENERGIZER CR2430
Specifications
mm (inches)
Lithium Coin
Safety:
(1) KEEP OUT OF REACH OF CHILDREN.  Swallowing may lead to 
serious injury or death in as little as 2 hours due to chemical burns and 
potential perforation of the esophagus.  Immediately see doctor; have 
doctor phone (202) 625-3333. 
Simulated Application test
Typical Performance at 21°C (70°F)
PRODUCT DATASHEET
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
200
400
600
800
1000
1200
V
o
lt
a
g
e
, CCV
Service, Hours
Load: 10K ohms - Continuous
Typical Drain @ 2.9V: 0.29 mA
0
20
40
60
80
100
120
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
50
100
150
200
250
300
IR
, o
h
ms
V
o
lt
a
g
e
, CCV
Capacity, mAh
IR
Pulse
Bkgnd
1-800-383-7323 USA/CAN
www.energizer.com
R1.30 (0.051) Ref.
R0.70 (0.028) Ref.
3.00 (0.118)
2.70 (0.106)
2.40 (0.094) Ref.
0.18 (0.007) Maximum Ref.
Permissible deflection from a flat.
8.00 (0.315)
Minimum
24.50 (0.965)
24.20 (0.953)
0.10 (0.004) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
2.20 (0.087) Ref.
This Battery has Underwriters 
Laboratories component Recognition
Form No. EBC - 4122H