6.4  
Fault 
Diagnosis 
 
When two cups of coffee / espresso are being prepared at the same 
time, the cups are filled unevenly. 
 
ƒ
  Appliance is not level. 
- Level the appliance 
 
ƒ
  Coffee nozzle is dirty. 
- Clean the coffee nozzle. 
 
Brew Unit cannot be removed from the appliance. 
 
ƒ
  The brew unit is not in the starting (home) position. 
- Reset the brew unit to the starting (home) position. 
 
ƒ
  The brew unit is jammed and cannot be removed by resetting the 
appliance (i.e. shutting the door and turn on the power). 
- Perform the manual removal procedure. 
Inspect the brew unit and/or drives to locate fault. 
 
Brew Unit cannot be installed 
 
ƒ
  The part marked PRESS was pressed during installation of the Brew 
Unit. 
- Do not press the part marked PRESS when installing the Brew Unit; 
this only applies during Brew Unit removal. 
 
ƒ
  The Brew Unit is not in the starting (home position). 
- Perform a manual resetting of the Brew Unit.  
 
ƒ
  The drive shaft is not in the starting (home) position. 
- Reset the Brew Unit to the starting (home) position via the Service 
Mode.  
- Carefully inspect the Brew Unit and/or drives to locate fault (i.e. 
defective switch etc...) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
103