Technical Information 
 
CVA615 Coffee System 
 
4.20.1  
Water Intake 
 
The Pump takes in water from the water tank. (The Pump is fitted with a 
safety valve which opens at approx. 16 bar (232 psi) system pressure. If 
the pressure is too high and the safety valve opens, water is drained off 
via a hose to the drip tray). 
 
 
4.20.2  
Water Path - Coffee 
 
The water is then pumped under pressure through the Flowmeter, and 
through the Coffee Flow Through Heater. The water is then passed 
through the Water Valve, into the Brew Unit. 
 
 
4.20.3  
Water Path – Hot Water 
 
The Pump moves water under pressure through the Flowmeter, and 
through the Coffee Flow Through Heater. The water is then passed via 
the Hot Water Valve to the Hot Water Outlet. 
 
 
4.20.4  
Water Path – Steam 
 
The pump moves water under pressure via the Flowmeter and through 
the Coffee Flow Through Heater. When the user selects steam; the 
Electronic energizes the Steam Valve. Water continues flowing through 
the Steam Flow Through Heater. Steam is then dispensed from the 
frothing nozzle. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 