Miele CVA615 Manual Do Utilizador

Página de 104
 
 
Technical Information 
 
CVA615 Coffee System 
 
5.21   
Brew Unit – Removal (NOT in Start/Home Position) 
 
Warning! 
This procedure will remove the brew unit from the appliance without 
damages. However, after the brew unit is removed, the drives must be 
carefully inspected (and repaired if necessary) then placed into the start 
(home) position via the service mode. 
 
Before proceeding close the front door, turn the power on to initiate a 
drive reset during the start-up sequence. 
 
Once “Ready...” is displayed; open the front door and attempt to Remove 
the Brew Unit – Refer to Section 5.20. If the brew unit still cannot be 
easily removed, perform the following: 
 
Refer to Figures 5-17 – Brew Unit and 5-18 – Brew Unit Connection 
Socket Retaining Screw and Locking Tab on the next page… 
 
1.  Open front door - Remove the Waste Container. 
2.  Locate the Philips screw (Figure 5-17, Item 2). 
3.  Remove the Philips screw. 
4.  Use a small flat tip screwdriver to left up on the locking tab (Figure 5-
18). 
5.  Grasp the brew unit handle and pull the brew unit out till the 
connection socket on the brew unit (Figure 5-17, Item 1) unsnaps 
from the brew unit and remains inside the appliance attached to the 
water nozzle. 
6.  Remove the Brew Unit – Refer to Section 5.20. 
7.  Slide the connection down to remove it from the appliance. 
8.  Re-install the connection socket to the Brew Unit. 
9.  Carefully inspect the drives for defects. 
10. Test the Home Position Switch and Brewing Position Switch for 
proper operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
65