Lincoln 1633-000-EA Manual Do Utilizador

Página de 32
Low Profile – 1600 Advantage Series Service Manual – International
 
11 
 
 
 
 
 
 
 
 
secondary readings are not achieved,  
 
 
 
 
 
 
 
 
replace transformer. 
 
 
 
 
Temperature display 
 
If proper voltage is present at terminals 
 
 
 
 
 
 
 
 
1,2, and 3 on temperature display, but 
 
 
 
 
 
 
 
 
but the display is not lighted, recheck 
 
 
 
 
 
 
 
 
all connections for tightness. If  
 
 
 
 
 
 
 
 
temperature display is still not operating, 
 
 
 
 
 
 
 
 
replace the temperature display. 
Temperature display 
 
Thermocouple   
 
Connect the thermocouple of a 
Inaccurate, erratic 
 
 
 
 
 
pyrometer to the thermocouple on 
Or inoperative   
 
 
 
 
 
the temperature control board. (be sure 
 
 
 
 
 
 
 
 
to maintain proper polarity of  
 
 
 
 
 
 
 
 
thermocouple leads—see adjustment  
 
 
 
 
 
 
 
 
section for proper procedure.) The 
 
 
 
 
 
 
 
 
pyrometer will indicate oven temperature 
 
 
 
 
 
 
 
 
display. Measure D.C. millivolts of 
 
 
 
 
 
 
 
 
thermocouple at the temperature display. 
 
 
 
 
 
 
 
 
See thermocouple chart in section D for 
 
 
 
 
 
 
 
 
proper readings. Replace thermocouple  
 
 
 
 
 
 
 
 
if proper readings are not achieved. If 
 
 
 
 
 
 
 
 
readings are correct on the thermocouple, 
 
 
 
 
 
 
 
 
replace temperature display.