Smeg P106NL Manual Do Utilizador

Página de 14
 
 
 
Instructions for the installer 
 
 
20 
2. Positioning of hob 
 
 
 
 
 
The following operation requires building and/or carpentry work so must be carried out 
by a competent tradesman. 
Installation can be carried out on various materials such as masonry, metal, solid 
wood or plastic laminated wood as long as they are heat resistant (T 90°C). 
 
 
2.1  Attachment to support structure 
Create an opening with the dimensions shown in the figure in the top surface of the 
counter, keeping a minimum distance of 50 mm from the rear border. This unit may be 
set against walls that are higher than the hob as long as distance “X” (see figure) is 
maintained to prevent damage to the walls due to overheating. Make sure there is a 
minimum of 750 mm between the hot plate flames and any shelf that may be installed 
directly above them. In case of installation on a hollow compartment with doors, a 
separating panel has to be placed under the hob. Keep a minimum distance of 10 mm 
between the bottom of the unit and the panel surface. The panel has to be easily 
removable to allow access in the event of technical service.