Lightolier 6310 Folheto

Página de 2
Lytespan
®
Track Lighting System
6310
Page 2 of 2
Basic Wall Washer
Lightolier 
a Genlyte company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • B1005
Job Information
Type:
Lighting Data
TRACK 2 FEET FROM WALL 
EXAMPLE: With multiple 75 watt R30 FL
units located 2" from wall, 2" on center
and aimed 60° from horizontal, the illumi-
nation on the wall 3" down from the ceil-
ing is 52 footcandles beneath fixtures and
49 footcandles between fixtures.
Footcandles are average and rounded off
and are based on a minum of five units.
For 100W R30 FL, multiply footcandles by
1.5.
Footcandles on Wall from Multiple Units ñ 75W R30 FL
1"
79
71
79
65
35
65
2"
78
65
78
60
37
60
3"
52
49
52
38
29
38
4"
29
31
29
21
21
21
5"
17
17
17
11
12
11
6"
12
13
12
8
8
8
7"
7
7
7
4
5
4
8"
5
5
5
3
3
3
9"
4
5
4
3
3
3
Distance From Ceiling
2"
2"
3"
60°
TRACK 3 FEET FROM WALL 
1"
34
32
34
29
17
29
2"
36
30
36
29
25
29
3"
34
26
34
27
21
27
4"
24
22
24
19
17
19
5"
17
16
17
14
11
14
6"
11
10
11
8
7
8
7"
8
8
8
5
5
5
8"
5
6
5
4
5
4
9"
5
6
5
4
3
4
Distance From Ceiling
3"
3"
4"
60°
2'
2'
3'
49 f.c.
52 f.c.