If the pump does not operate after 
repeated attempts, check the following:
1.  Vertical distance of pump to water 
level must not be over 25 feet.
2.  Suction piping must be air tight.
3.  Be sure valve(s) are open if used in 
discharge or suction piping.
 
Never run the 
  pump with a closed 
or clogged discharge. The water inside 
the pump could boil and damage the 
pump.
Maintenance
Maintain adequate ventilation for the 
pump motor. The motor bearings are 
permanently lubricated at the factory. 
Additional lubrication is not required.
DRAINING FOR WINTER
Always protect pump and piping 
against freezing temperatures. If there 
is any danger of freezing, drain the 
system. To drain the system:
1.   Remove the pipe plug from the 
discharge tee.
2.   Remove the 1/4” plug from the 
lower front face of the pump.
3.   Drain all piping below the frost line.
3
Operating Instructions and Parts Manual 
pump in accordance with the National 
Electrical code and all applicable local 
electrical  codes. 
The motor must be grounded by 
connecting a copper conductor to the 
grounding screw provided within the 
wiring compartment.
The voltage of power supply must match 
the voltage of the pump. The WLS75, 
WLS100 and WLS150 have dual voltage 
motors preset at the factory to 230 volts. 
The motors can be converted to 115 volts 
by turning the voltage selector to the 
desired voltage (See Figure 5).  Use a 
needle nose pliers to pull the selector out 
approximately 1/4”, rotate and then 
reinsert in correct position. The WLS200 
cannot be converted; the motor is 
230 volts only
.
CONNECTING WIRES
Terminal cover must be in place for safe 
operation. Ground in accordance with local 
and national electrical codes. Keep fingers 
and objects away from openings and 
rotating parts. Disconnect power sources 
before touching internal parts. See figure 6 
for appropriate wiring locations.
Operation
 
Never run the 
  pump dry. Running 
pump without water may cause seal 
damage. Fill the pump with water 
before starting.
PRIMING THE PUMP
After pump installation is complete, the 
pump must be primed. Remove the 
pipe plug in the discharge piping and 
fill the pump and suction pipe with 
clean water. Turn power to pump on. If  
the pump does not pump water in 10 
minutes, turn off the pump and refill 
with clean water.
115 V
230 V
115 V
230 V
Figure 5 - Voltage Selector
Electrical Connections 
(Continued)
 
Lift 
in 
Feet
3/4 HP Pump Capacity in 
GPH Operating Pressure (psi)
10
20
30
5
3900
3320
2320
10
3780
3120
2100
15
3600
2910
1190
20
3250
2670
  990
25
3010
2560
  840
Lift 
in 
Feet
1-1/2 HP Pump Capacity in 
GPH Operating Pressure (psi)
10
20
30
40
5
4790
4480
3480
2060
10
4610
4310
3190
1520
15
4320
4040
2900
0
20
3900
3720
2680
0
25
3810
3300
2390
0
Lift 
in 
Feet
2 HP Pump Capacity in GPH 
Operating Pressure (psi)
10
20
30
40
5
5980
5560
4310
3060
10
5410
5220
4090
2880
15
5230
4980
3900
2570
20
4120
3840
3510
2210
25
3980
3600
3300
0
Lift 
in 
Feet
1 HP Pump Capacity in GPH 
Operating Pressure (psi)
10
20
30
5
4410
3920
2570
10
4180
3520
2300
15
3830
3340
1780
20
3680
3060
1160
25
3340
2720
1260
www.waynepumps.com
WLS75, WLS100
WLS150, WLS200
Figure 6 - Connecting Wire
Ground Screw
Ungrounded 
Line (L1)
Terminal 
Board (L2)