Replace the transducer, making sure the electrical connections are located on the outside 
(back) edge of the cubic design.  Tighten the 4-40 standoff screw snugly (finger tight plus 
¼ turn). 
 
 
(8) 
Reattach the flex circuit, ensuring it is attached to the same pins from which it was 
removed, and that the pins are not bent.  Replace the 3/32" Allen-head stabilizing screw 
into each of the transducer 4-40 standoffs. 
 
 
(9) 
Ensure all back panel electrical connections are in place, and replace the back panel by 
sliding it into position and re-installing the eight (8) Phillips-head retaining screws. 
 
 
(10)  Test your 98RK-1 Scanner Interface Rack to ensure proper operation. 
 
5.1.7  
Front Pull-out Slide Tray 
 
The front pull-out slide tray contains the PC-363 Ethernet controller board and the 98RK-1 
power supply.  Neither of these components is considered to be field-repairable. If it is 
determined that maintenance is required on either of these units, the entire pull-out tray should 
be returned to Pressure Systems for replacement. 
 
Switches for setting Cluster and Rack (physical) addresses are located on the PC-363 board 
(Cluster address) and on the front panel (Rack address).  See Chapter 3, “Read Module 
Status” (Command ‘q’)
 for more information regarding scanner physical addresses.