Configuration 2: R7r (+CMS) <—ethernet—> R7csi 
87
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Switch 2 Task— Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 2 for the ethernet connection 
to Switch 1. The data module associates a link number with a port address, extension 
number, and node name for the C-LAN port used for this connection.
Begin
Steps
Open Data Module form — enter 
ad da n
[This data module is assigned the next available extension, 3020.]
> Enter values
> Submit the screen
End
add data next 
                                                                  Page 1 of X
                      
 DATA MODULE
    Data Extension: 3201
 Name: ethernet on link 5
 
 Type: ethernet
              Port: 01a0517_
              Link: 5 
Network uses 1’s for broadcast addresses? y
Field
Conditions/Comments
Type:
This indicates the data-module type for this link.
Port:
Ethernet connections must be assigned to port 17 on the C-LAN 
circuit pack. In this example, the C-LAN circuit pack is in slot 
1a05.
Link:
The link number must be in the range 1 – 25 (R8csi), not 
previously assigned on this switch.
Name:
Information-only; appears in list generated by the “list data 
module” command.
Network uses 
1’s for 
broadcast 
addresses?
Leave the default (
y
) if the private network contains only 
DEFINITY switches and adjuncts. Set to 
n
 only if the network 
includes non-DEFINITY switches that use the 0’s method of 
forming broadcast addresses. See Appendix A, “Data Module - 
type ethernet” for more information about this field.