Configuration 2: R7r (+CMS) <—ethernet—> R7csi 
3  
C-LAN Administration
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
98
Enable links and processor channels
You must enable links and processor channels before the connections can be used.
To enable a link, open its data module screen (
ch da
 [
ext
]) and set the Enable 
Link? field to 
y
[note: to view a list of assigned data modules and their extensions, enter the “list 
data-module” command (
l da
)]
To enable the processor channels, open the processor channel screen (
ch com p
and set the Enable field to 
y
 for each assigned processor channel.
Note:
1. You must disable a link or processor channel before you can change its 
parameters.
Note:
2. The busy-out command overrules the data module Enable Link? field.
Note:
3. On the C-LAN boards, low-level connectivity can remain intact when 
higher-level applications such as DCS are not functioning. For example, 
an external ping to a C-LAN’s ethernet port could be successful even 
when the board is busied-out. When debugging connectivity problems, 
pinging only checks low-level connectivity.