Lucent Technologies Release 8.2 Manual Do Utilizador

Página de 524
Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs) 
<—ethernet—> R8si 
3  
C-LAN Administration
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
184
Switch 1 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 1. Note that there are no processor channels or interface channels associated 
with the ppp connection between the two C-LAN circuit packs.
Begin
Steps
Open the Processor Channel Assignment form — enter  
ch com p
.
> Enter values
change communications-interface processor-channels
                                                                    Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc                Gtwy 
Interface    Destination      Session    Mach
Chan Enable  Appl.  To  Mode  Link/Chan   Node 
Port  Local/Remote  ID
  1: 
_______ 
 _    __  _____  _________  0____  ___   ___    __
  2: 
_______ 
 _    __  _____  _________  0____  ___   ___    __
  3: 
_______ 
 _    __  _____  _________  0____  ___   ___    __
  :
 12: 
y dcs____  
1_  5003_  node-2___ 0
 12_   21_    2_
 13: 
y
 
dcs ___
s
2   5003__ node-3___  0
 13_   31_    3_
:
384: n 
_______ 
 _    __  _____  _________  0____  ___   ___    __
Field
Conditions/Comments
Processor Channel 12
: (ppp connection to Switch 2)
Enable
Set to 
y
.
Appl.
Set to 
dcs
 for DCS signaling.
Mode
Node-1a is the “server” for this session. Set node-2 to “client” 
(
c
).
Interface Link
This must match the link number assigned on the node-1a 
data module screen.
Interface Chan
For TCP/IP, interface channel numbers are in the range 5000 
– 64500.
The recommended values are: 5001 for CMS, 5002 for Intuity 
AUDIX, and 5003 for DCS connections that are not 
gateways. These three values should be reused for multiple 
instances of these applications; for example, if there are two 
Intuity AUDIX’s, use 5002 for both; or if there are four 
DEFINITY ECS’s, use 5003 for all four. The combination of 
Link, Interface Channel, and Mach ID must be unique.
This number must match the Destination Port number on the 
Switch-2 Processor Channel screen
1 of 3