Other Networking-Related DEFINITY Screens 
305
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
A  
Screens Reference
Primary
Enter the 5-character circuit pack location number for the circuit pack that will 
function as the primary synchronization source. The clock circuit pack’s internal 
source is the implicit last choice. Only one switch in the network can function as the 
primary synchronization source. Only displays when the Stratum field is 
4
.
The Primary and Secondary synchronization sources (DS1 or BRI trunk facilities) 
must be on the same Port Cabinet (that is, PPN, EPN1, or EPN3).
Secondary
The system will select automatically the secondary circuit pack if the primary circuit 
has a failure. Only displays when the Stratum field is 
4
.
The Primary and Secondary synchronization sources (DS1 or BRI trunk facilities) 
must be on the same Port Cabinet (that is, PPN, EPN1, or EPN3).
Pages 1–X of the screen
Location/Name
Identifies the location and name for each DS1 or BRI trunk circuit pack administered 
via the DS1 or BRI Trunk Circuit Pack screen. Only displays if the Stratum field is 
4
.
Valid entries
Usage
01
 through 
44 
(G3r)
First and second characters are the cabinet number
01
 through 
03
 (G3si)
A
 through 
E
Third character is the carrier
01
 through 
20
Fourth and fifth characters are the slot number
blank
A blank entry means no external source.
Valid entries
Usage
01
 through 
44
 (G3r)
First and second characters are the cabinet number
01
 through 
03
 (G3si)
A
 through 
E
Third character is the carrier
01
 through 
20
Fourth and fifth characters are the slot number
blank
A blank entry means no external source.
Valid entries
Usage
Display-only field.