346
Extension Number Portability
Extension Number Portability (ENP) gives you the ability to assign any extension to 
any switch in an ENP subnetwork. Stations can be moved across switches while 
retaining the original extension number, as long as the switches are part of the ENP 
subnetwork. EPN is used in conjunction with Automatic Alternate Routing (AAR) 
and Uniform Dial Plan (UDP). 
How to administer ENP
AAR Digit Conversion form — Assign all 3-digit ENP codes as home, and if using 
a 5-digit UDP, associate the ENP codes with the leading, or 10 thousands, digit 
(that is, the fifth digit of the extension). For example, for extension number 73446, 
“7” is the 10 thousands digit.
ENP Numbering Plan form — Associate the leading one or two digits of 
extensions in the ENP subnetwork with a 3-digit ENP code, used to construct a 
7-digit AAR-like ENP number.
Node Number Routing form — Associate a route pattern with each node in the 
ENP subnetwork.
Uniform Dialing Plan form — Enter the number of digits in the plan (4 or 5) and 
the Extension Codes for non-home extensions in the ENP subnetwork as 
ENPNode (node number routed).
Detailed description
The ENP Numbering Plan allows you to set 4- or 5-digit extensions in the ENP 
subnetwork to a 7-digit AAR-like number that is sent to other nodes in the network. 
Only the first 1 or 2 leading digits of the extension are significant. 
ENP Codes are distinguished from AAR location codes because ENP Codes are home 
on every node within the ENP subnetwork, and ENP Codes are administered in the 
ENP Numbering Plan table as well as in the AAR Analysis table. Since ENP Codes 
are home on every node, they cannot be used as AAR location codes.
UDP extensions are converted to ENP numbers if node number routing is specified 
for the extensions in the UDP table. 
Note:
One ENP code is required for a 4-digit ENP subnetwork. A 5-digit 
UDP requires one ENP code for each leading digit of extensions 
used within the ENP subnetwork.
DCS message signaling links are not required to support ENP. As a result, many 
multiple switch configurations are possible with ENP. Typically the ENP network 
will be a subnetwork of a UDP or Electronic Tandem Network (ETN).
Form
Field
AAR and ARS Digit Conversion Table
All
Extension Number Portability Numbering 
Plan
All
Node Number Routing
All
Uniform Dialing Plan 
Ext Code