Installation Manual
Section 1:  Introduction
SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by default. Enabling Telnet on 
the SEG allows you (the customer) to be able to configure the settings of the SEG via LAN without requiring the serial connection to 
the SEG via the “Gateway Config” RJ11 adapter. While enabling Telnet setup was done as a convenience to speed setup, it also opens 
a security hole in the SEG.  It is recommended that when you are finished setting up the SEG, that you also enable the Telnet 
password option, so that a password is required to enter Telnet in the future. This Telnet password option is located in Setup menu 
option named “0 Server Configuration” and when you get to “Change telnet config password” enter Y and then enter a 4 digit 
password. You can also completely disable Telnet in the menu named “6 Security”.
The SEG is a LAN/WAN (TCP/IP to serial) interface that enables existing or new IEI access systems to use the end user's network 
infrastructure and to be programmed and managed at any network PC running Hub Manager™ Professional software. The SEG 
requires Hub Manager™ Professional software version 5.0 or higher for static IP addressing and version 7.1 or higher for dynamic 
addressing. The access system data sent over the corporate network is 128-Bit so that user and door information cannot be "sniffed" 
and security compromised.
The IP address assigned to the SEG may be either a static address assigned by authorized network administrator, or  it may be a 
dynamic address assigned by a DHCP Server.
IMPORTANT NOTE:
To set up the SEG, installation technicians must have a technical knowledge of networks and networking in a PC environment. It is 
important to consult the end user's system administrator in order to resolve any networking issues that may occur.
Ordering Information
Model
p/n
Description
SEG-1
0296005
IEI Secured Ethernet Gateway. Converts TCP/IP to serial data enabling IEI access 
systems to use a network to securely send and receive data; and to be programmed and 
managed from any network PC running Hub Manager Professional. Requires network 
connection. Wall mounts using separately provided hardware; requires separate 12VDC 
power [150 mA max], provided with modular cord for communication with access 
panel.
SEG-M
0296006
IEI Secured Ethernet Gateway [Plug-in] Module. Converts TCP/IP to serial data 
enabling IEI access systems to use a network to securely send and receive data; and to 
be programmed and managed from any network PC running Hub Manager Professional. 
Requires network connection. Easily plugs into backplane which provides module 
power and communication with access panel.