Troubleshooting
Use the table below to troubleshoot common problems. If you still experience 
problems, please contact Avaya’s Technical Support.
Table B.1
Troubleshooting Tips
Problem
Probable Cause
Solution
1)The ATM Access 
module IP does not 
answer Ping 
(general)
1)Not inserted 
correctly in M770 
switch.
2)No power
3)Incorrect IP 
parameters
1)Check that it is inserted all the 
way into the switch and that the 
screws are tightened.
2)Verify IP configuration by 
connecting a terminal to the 
M-ACC Access module’s Console 
port. Check whether IP and 
gateway addresses have been 
defined for the module.
3)Check that the OPR and ATM 
LEDs are ON?
2)No response to ping 
when your PC is 
connected via a 
Cajun M770 
X-Switch Ethernet 
Port
1)VLAN of the port 
is not set to 
VLAN 1
1)VLAN of the port is not set to 
VLAN 1
3)No response to ping 
when the pinging 
station is in the 
ATM network
ELAN default state 
is either down or 
disable
1)Set ELAN default to the up state
2)Check the ATM switch 
configuration
LNK LED is blinking 
even though cable is 
connected
Incompatible port 
speed
Check the speed of the ATM Access 
module port and ATM switch
ELAN/VLAN 
Association problems
Misconfiguration of 
LANE services to 
this ELAN
Check ATM switch LANE 