GarrettCom MNS-6K-SECURE 14.1.4 Manual Do Utilizador

Página de 364
U P D A T I N G     S O F T W A R E   –   S T E P   2  
343 
 
F
IGURE 
159  - HyperTerminal screen showing the serial settings 
 
Network Access 
Prerequisites - a PC (or workstation/computer) with telnet software and the IP address of 
the Magnum 6K switch (or DNS name associated with the switch) to be upgraded.  
Access the Magnum 6K switch by using the telnet command. For example, if the switch 
has the IP address 192.168.10.11 the command is as shown in Figure 6 below. 
C:> 
telnet 192.168.10.11
 
Trying …..   connected… 
F
IGURE 
160
 
– Using telnet command to connect to a Magnum 6K switch with IP address 
192.168.10.11 
 
 
If the telnet command does not work – check for network connectivity 
(using the ‘ping’ command). Please ensure that a personal firewall or other 
firewall settings are not affecting ping or telnet commands. If telnet 
services fail
 then the alternative is to locate the Magnum 6K switch and 
update the MNS-6K software through the serial port following the serial 
update process described in this document.
 
Saving the Configuration 
Before saving the configuration, please ensure that one of the three capabilities listed below are 
available 
                                                                          
10
 telnet services can fail due to a number of reasons. Please check with your system and/or network administrator for 
additional help.