Renesas M30240T-RPD-E Manual Do Utilizador

Página de 58
( 25 / 58 )
3.3 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.2 lists the factory-settings of each clock
supply.
Table 3.2 Clock supply to the MCU
IMPORTANT
Notes on Changing the Clock Supply:
• The clock supply can be set by the Init dialog when starting up the emulator debugger
or inputting CLK command on the script window.
Clock
Description
Display of emulator debugger
Default setting
X
IN
-X
OUT
Internal oscillator circuit of emulation pod
(OSC-2: 12MHz)
Target system
Internal
External
Yes
-