IBM AT-FS202SC/FS3 Manual Do Utilizador

Página de 44
AT-FS20x Series Installation Guide
13
Note
See “Fiber Optic Port Specifications” on page 22 for additional 
information on the fiber optic port.
AT-FS202
50/125 or 62.5/
125 micron 
multimode
2 km (1.2 mi)
13 dB at 1310 nm
AT-FS202SC/FS1
50/125 or 62.5/
125 multimode
2 km (1.2 mi)
13 dB at 1310 nm
9/125 micron 
single-mode
15 km (9.3 mi)
16 dB at 1310 nm
AT-FS202SC/FS2
9/125 micron 
single-mode
40 km (24.8 mi)
30 dB at 1310 nm
AT-FS202SC/FS3
9/125 micron 
single-mode
75 km (46.5 mi)
33 dB at 1310 nm
AT-FS202SC/FS4
2
9/125 micron 
single-mode
100 km (62 mi)
34 dB at 1550 nm
1.  Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical 
fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at 
the operating optical wavelength.
2.  The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted 
single-mode fiber optic cable.
Model
Cable Type
Maximum 
Operating 
Distance
1
Maximum 
Allowable Loss 
Budget