Chapter 5: Local Management
5-30
2H23-50R/2H33-37R User’s Guide
5.7.10.1 Changing the COM Port Application
After enabling the COM port as described in 
, one of the 
applications supported by the COM port (LM or UPS) can be selected. 
The default application is LM.
To change the COM port application: 
1.
Use the arrow keys to highlight the Application field.
2.
Use the SPACE bar or BACKSPACE to step through the available 
settings until the operation you require displays. 
 lists the 
available settings and their corresponding applications. 
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight the SAVE command at the bottom of 
the screen, then press the ENTER key. The message “SAVED OK” 
displays, indicating that the edits are saved.
5.7.11
Clearing NVRAM
Clearing NVRAM allows the user to clear all user-entered parameters, 
such as the IP address and Community Names from NVRAM.
Table 5-3
COM Port Application Settings
Setting
Application
LM
Local Management Session
UPS
APC Power Supply SNMP Proxy
!
CAUTION
When the COM port is configured to perform the UPS 
application, all future Local Management connections must be 
made by establishing a Telnet connection to the device. Ensure 
that the device has a valid IP address before saving changes to 
the COM port application. If the device does not have a valid IP 
address and the changes are saved, refer to 
 for 
instructions on clearing NVRAM in order to reestablish COM 
port communications.
!
CAUTION
Clearing NVRAM results in the loss of all user-entered 
parameters. Do not proceed unless the following procedure is 
completely understood.