Tektronix 2200 Manual Do Utilizador

Página de 188
4-22
Section 4 — Maintenance
Replacing Either Control Panel Power Supply
To replace either control panel power supply proceed as follows: 
1. Open the control panel and turn the AC power switch(es) on the left 
front of the enclosure to the OFF position. See 
2. At the rear of the control panel, disconnect the power cord(s) from the 
AC source. 
WARNING
If the redundant power supply is installed, both power supplies must be 
turned off and both power cords must be disconnected. 
3. Remove the enclosure covering the power supplies by removing the 
screws securing it to the control panel frame. See 
NOTE:  
Removing some control panel internal ribbon cables may make removing 
the power supply enclosure easier. 
Control Panel
CPU Board
Power
ON/OFF
Switch
Fuse
Control Panel
Power Supply
Cover
Fan
Power Switch
& Fuse
(Optional
Redundan)
Power Supply
(Standard)
Power Supply
(Redundant)
Figure 4-9.  Control Panel AC Power Switch Location