Installation
Installation
The following procedures contain the instructions necessary to install the 
control panel, switcher frame, and frame power supply. Procedures are 
also included for optional circuit modules and cable installation. Before 
proceeding, read and understand all precautions and notes.
Control Panel Installation
This installation does not require countersunk or beveled edges. The tub 
slips into the cutout from the top and is held in place by an overhanging lip 
secured by six screws. To install the control panel in the console, proceed 
with the following steps. 
NOTE:  
The control panel should be installed on as flat a surface as possible. It is 
not recommended to have more than a 10 degree tilt, as this would add excessive 
weight on the gas shocks supporting the control panel top.
Be sure to leave a minimum of 6.0” (153 mm) of clear space inside the console 
behind the control panel for control, signal, and power cables and connectors.
 Also, be sure to leave a minimum of 5.2” (152 mm) of clear space behind the 
control panel so the lid can be fully opened, as shown in 
Figure 2-1.  Model 2200 Control Panel Profile
23.5"
(596 mm)
2.2"
(56  mm)
1"
(25  mm)
8.0"
(203 mm)
23.5"
(597 mm)
5.2"
(152 mm)
5.8"
(146  mm)
13.8"
(350 mm)