Section 2 — Installation
Secondary Wipe Pattern Generator Options
The Secondary Wipe Pattern Generator option for the Model 2200 provides 
a second wipe for each Mix/Effects. It consists of two mezzanine modules 
which mount on the Mix/Wipe Modules for M/E 1 (Slot A8) and M/E 2 
(Slot A12). Refer to 
 for the Mix/Wipe module locations.
The Secondary Wipe Pattern Generator Mezzanines mount next to the 
Primary Wipe Generator Mezzanines already present on each Mix/Wipe 
Module. The Look Ahead Preview Option Mezzanines described later also 
mount on each Mix/Wipe Module. Refer to 
.
To install the Secondary Wipe Pattern Generator Mezzanine modules, 
carefully remove the correct Mix/Wipe Modules from the front bay of the 
switcher frame. Place them on a static free surface.
1. Line up the Mezzanine Module so that Connector J1 on the Mezzanine 
aligns with J10 of the Mix/Wipe Module. Note that the keying plug on 
J1 will mate with the missing pin on J10. Line up the two 50-pin 
connectors on the Secondary Wipe Pattern Generator mezzanine with 
the matching connectors on the Mix/Wipe Module. Be sure the pins are 
lined up properly before seating the mezzanine (look between the 
mezzanine and the main module). Check that no pins are bent or 
outside of the connectors. Push down firmly to seat the mezzanine to 
the module.
Figure 2-15.  Borderline Option Mezzanine Installation
BORDERLINE MEZZANINE
KEYER MEZZANINE