Tektronix 2200 Manual Do Utilizador

Página de 188
2-48
Section 2 — Installation
Status Terminal Connections
The Status Terminal connector on the rear of the control panel allows the 
connection of a VT-100 (type) terminal to be connected to the Model 2200. 
The terminal is used to monitor system status and for maintenance 
purposes.
1. Connect a cable between the input of a VT-100 (type) terminal and J3 
(Status Terminal connector) on the rear of the control panel. The 
connector (J3) on the rear of the control panel is a standard RS-232 
configuration via a DB-25 connector with the following pin-outs:
Pin 1
 — Protective Ground
Pin 2 
— TxD (From the Terminal)
Pin 3
 — RxD (To the Terminal)
Pin 7
 — Signal Ground
2. Ensure that the baud rate and other parameters of the Model 2200 given 
below match the baud rate of the terminal. See the Owner’s Manual of 
the terminal in use to determine or set the baud rate of the terminal. 
Also be sure the terminal is set to “Newline Off” or “No Newline”.
9600 baud 
8 data bits 
1 stop bit 
No parity 
Analog Reference Connection
Connect an analog signal such as color black or any other stable analog 
signal to either J5 or J6, ANALOG REF IN, on the Com I/O Module in Slot 
C10. Terminate any unused BNC connectors.