Tektronix 2200 Manual Do Utilizador

Página de 188
2-61
Cable Connections
The Control cable is connected between the Peripheral Port (J5) at the rear 
of the DPM frame, and Port A3 (J5) on the Expanded Communications 
Panel at the rear of the switcher frame. See 
.
The DPM-700 connects to the switcher frame through a control cable 
available from GVG. Available cable length is 16 meters (054602-16). 
Alternatively, you may make your own cable, as illustrated in 
Maximum length of the control cable is 300 meters.
Video Production Editor Connections
The Model 2200 may be connected to video editors such as GVP’s VPE-
series of editors. Refer to 
 while making this connection.
1. Attach the signal cable from the editor to the EDITOR port (J3) located 
on the Communications I/O Module in slot B10.
2. The EDITOR INTERFACE menu for assigning baud rate and parity is 
found under the EXTERNAL I/F section of the CONFG menus. Refer 
to System Setup later in this section.
Figure 2-30.  Peripheral Bus II Cable Design
Chassis Ground
Ground
Connects to 
PORT A3
on Model 2000
1
2
6
7
3
8
4
9
5
Rx B
Tx A
Tx B
Male
(Twisted Pairs)
Rx A
Connects to
J5 on
DPM 100/700
1
2
6
7
3
8
4
9
5
Male
Wiring
Side
Wiring