TP-LINK T1500-28PCT Manual Do Utilizador

Página de 200
 
128
 
system power limit, the PD linked to the port with lower priority will be 
disconnected. By default, the priority level is “low”. 
Command Mode 
Interface Configuration Mode (interface fastEthernet / interface range 
fastEthernet) 
Example 
Configure the PoE priority as “low” for port 2: 
T1500-28PCT(config)# interface fastEthernet 1/0/2 
T1500-28PCT(config-if)# power inline priority low 
power inline supply   
Description 
The 
power inline supply command is used to configure the PoE status of the 
corresponding port. 
Syntax 
power inline supply { enable | disable } 
Parameter 
enable | disable —— The PoE status of the port. By default, the PoE status is 
“enable”. 
Command Mode 
Interface Configuration Mode (interface fastEthernet / interface range 
fastEthernet) 
Example 
Enable the PoE feature for port 2: 
T1500-28PCT(config)# interface fastEthernet 1/0/2 
T1500-28PCT(config-if)# power inline supply enable 
power inline profile 
Description 
The 
power inline profile  command is used to bind a PoE profile to the 
corresponding port. To cancel the bind relation, please use 
no power inline 
profile command.