Minuteman UPS ED6000T Manual Do Utilizador

Página de 23
 
6
 
15 
 
ON and Alarm Silencer Switch 
16 
 
OFF Switch 
17 
 
Previous Page or Setting Change 
18 
 
Next Page 
19 
 
Special Function Log in /out 
20 
 
Enter or Reconfirmed 
21 
 
Utility Input Normal LED 
22 
 
Bypass Input Normal LED 
23 
 
UPS under Redundancy Mode 
24 
 
UPS under ECO Mode 
25 
 
UPS Fault or Abnormal Warning LED 
26 
EPO 
Emergency Power Off 
27 
Er01 
DC BUS capacitor pre-charge abnormal after 
50-seconds or Battery Fuse failure 
28 
Er02 
AC SCR or Battery SCR soft Start abnormal
after 2-seconds 
29 
Er03 
PFC (Boost) soft start abnormal after 30-
seconds  
30 
Er04 
Inverter Failure 
31 
Er05 
Battery Weak or Dead 
 
7
 
32 
Er06 
Output Short Circuit 
33 
Er08 
DC Bus high-voltage-level abnormal 
34 
Er09 
DC Bus low-voltage-level abnormal 
35 
Er10 
Inverter Over-current 
36 
Er11 
UPS Overheated 
37 
Er12 
Inverter Overload 
38 
Er13 
Charger Failure or Abnormal   
39 
Er14 
Fan Failure 
40 
Er15 
Wrong procedure to enter Maintenance Mode 
41 
Er16 
Output parameters Set error in Parallel System 
42 
Er17 
ID numbers are in conflict in Parallel System or 
ID number error in single unit 
43 
Er18 
EEPROM data error. Its values are reset to 
default (Normal / 220V / adj0% / +/-3Hz / low 
sensitivity) 
44 
Er20 
DC Bus voltage cannot be discharged 
45 
Er21 
Parallel communication error (communication 
wire disconnected or failure to find ID1 UPS) in 
parallel system 
46 
Er22 
Bypass SCR or Output Fuse Fails 
47 
Er23 
Inverter Relay or SCR or Output Fuse Fails