Renesas HD74LV2GT04A Manual Do Utilizador

Página de 8
HD74LV2GT04A
Rev.2.00,  Oct.14.2003,  page 4 of 7
Recommended Operating Conditions
Item
Symbol
Min
Max
Unit
Conditions
Supply voltage range
V
CC
3.0
5.5
V
Input voltage range
V
I
0
5.5
V
Output voltage range
V
O
0
V
CC
V
6
V
CC
 = 3.0 to 3.6 V
I
OL
12
V
CC
 = 4.5 to 5.5 V
–6
V
CC
 = 3.0 to 3.6 V
Output current
I
OH
–12
mA
V
CC
 = 4.5 to 5.5 V
0
100
V
CC
 = 3.0 to 3.6 V
Input transition rise or fall rate
t / 
v
0
20
ns / V
V
CC
 = 4.5 to 5.5 V
Operating free-air temperature T
a
–40
85
°C
Note:
Unused or floating inputs must be held high or low.
Electrical Characteristic
  Ta = –40 to 85°C
Item
Symbol V
CC
 (V) *
Min
Typ
Max
Unit Test condition
3.0 to 3.6
1.5
V
IH
4.5 to 5.5
2.0
3.0 to 3.6
0.6
Input voltage
V
IL
4.5 to 5.5
0.8
V
3.3
0.10
Hysteresis voltage
V
H
5.0
0.15
V
V
T
+
 – V
T
Min to Max
V
CC
–0.1
I
OH
 = –50 
µ
A
3.0
2.48
I
OH
 = –6 mA
V
OH
4.5
3.8
I
OH
 = –12 mA
Min to Max
0.1
I
OL
 = 50 
µ
A
3.0
0.44
I
OL
 = 6 mA
Output voltage
V
OL
4.5
0.55
V
I
OL
 = 12 mA
Input current
I
IN
0 to 5.5
±1
µ
A
V
IN
 = 5.5 V or GND
Quiescent
supply current
I
CC
5.5
10
µ
A
V
IN
 = V
CC
 or GND,
I
O
 = 0
I
CC
5.5
1.5
mA
One input V
IN
 = 3.4 V,
other input V
CC
 or GND
Output leakage current I
OFF
0
5
µ
A
V
I
 or V
O
 = 0 to 5.5 V
Input capacitance
C
IN
5.0
3.0
pF
V
IN
 = V
CC
 or GND
Note:
For conditions shown as Min or Max, use the appropriate values under recommended operating