Toshiba PSAGEX Manual Do Utilizador

Página de 263
2.5      2.5-inch HDD 
2  Troubleshooting 
 
 
Procedure 4 Test Program Check 
Run the HDD test program stored on the maintenance test program disk for all test items.  
See Chapter 3 for details on how to use the test program. 
If an error is detected during the HDD test, an error code and status will be displayed.  The 
error codes and their status names are listed in Table 2-1.  If an error code is not generated 
and the problem still exists, go to Procedure 5. 
 
Table 2- 1 HDD error code and status 
 
 
Code
 
Status
Get Parameter Fail !
1
2
Read Old Data Error
Write Pattern Error
3
4
Read Back Data Error
Data Compare Error
5
Restore Data Error
6
7
Read Verify Error
9
Seek Error
 
Disk Controller Self Test Failed
10
11
Disk Controller Test unexpected interrupt Failed
Disk Controller action Test Failed
12
13
Disk dos not support SMART
Disk read attribute threshold error
14
15
Disk read attribute value error
16
Disk SMART attribute  value error
Satellite A300/Satellite Pro A300/EQUIUM A300/SATEGO A300   Maintenance Manual 2-13