Toshiba ProT1!0 Manual Do Utilizador

Página de 279
Test Program for Field. 
3.18  Log Utilities 
This function logs error information generated while a test is in progress and stores the 
results in RAM (Maximum error log : 500 times). This function can store data on a floppy 
disk. If the power switch is turned off, the error information will be lost. Error information is 
displayed in the following order: 
 
1.  Error count (CNT) 
2.  Test name and subtest number (TEST) 
3.  Pass count (PASS) 
4.  Error status (STS) 
5.  FDD/HDD or memory address (ADDR) 
6.  Write data (WD) 
7.  Read data (RD)   
8.  Error Name ( ERROR NAME/DETAILS)   
 
3.18.1 Operations 
1.  Select 04 and press Enter in the Diagnostics Menu to log error information into 
RAM or onto a floppy disk. Error information is displayed in the following format: 
 
XXXX ERRORS    
 
PASSCOUNT = XXXX 
CNT TEST 
PASS STS ADDR 
WD RD ERROR 
NAME/DETAILS 
001 FDD 
02 0000 180 0000001 00 00 WRITE 
PROTECTED 
002 FDD 
01 0000 120 0000001 00 00 TIME 
OUT 
ERROR 
 
 
 
 
 
 
 
   
 
  Address 
   
   
 
Error 
Status 
   
   
Pass 
Count 
 
   
 
   Subtest Number 
 
 
Read Data 
 Test 
Name    
Write 
Data 
Error Count 
 
 
 
 
 
    Error Name and Detail 
[[1:Next, 2:Prev, 3:Exit, 4;Clear, 5:FD Log Read, 6:FD Log Write, 7:Log Save]]
 
 
 
 
 
Satellite T110 and Satellite Pro T110 Tests and Diagnostics Manual 
63