Network Computing Devices LSQ-40L Manual Do Utilizador

Página de 27
 
 
NOTE: If you are already using a network connection for another application, you 
may want to create a new connection and configure it for scale communications. 
 
CONFIGURING YOUR NETWORK ON THE SCALE: 
 
 The scales network IP address should already be configured from the factory. If 
you want to check it or if you are using more than one scale, follow the procedure 
below. 
 
TO SEE/CHANGE SCALES IP ADDRESS: 
 
1). If the scale is on, turn it off. 
 
2). Turn on the scale. During the countdown, press and release the following keys in 
sequential order. Press X, +, and then AGENT before the countdown completes. 
 
3). Display should go blank. Enter 2005 and press PRINT. 
 
4). Press PRINT to scroll thru the address numbers. At any time you may change 
them by entering the new numbers. The first scales address should be 131.1.100.101. 
 
5). Press ESC when complete. 
 
 If you are using more than one scale on the network, then each scale must have its 
own network address. EXAMPLE:  SCALE#1 
131.1.100.101 
      
 
SCALE#2 
131.1.100.102 
      
 
SCALE#3 
131.1.100.103 
 
NOTE: You should write down each address. You will need to type it in again later 
to add them to the network. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page 8