Citizen CT-S300 Manual Do Utilizador

Página de 158
— 119 —
DLE DC4 fn d1...d7 (Specification of fn = 8)
[Function]
Buffer clear
[Code]
<10>H<14>H<fn><d1> ...<d7>
[Range]
fn = 8, d1 = 1, d2 = 3, d3 = 20, d4 = 1, d5 = 6, d6 = 2, d7 = 8
[Outline]
• Erases all data in receiving buffer or print buffer.
• Sends the following 3-byte data group.
Hex.
Decimal
No. of Data
Header
37H
55
1 byte
Identifier
25H
37
1 byte
NULL
00H
0
1 byte
• Enters the state of selecting STANDARD MODE.
[Caution]
• When receiving a code row coinciding with the code configuring this command,
the same operation as this command takes place and attention by the user is
required.
Example: When corresponding code row is present in bit image data.
• This command must not be used between other command code rows.
Example: This command is used in bit image data.
• This command is ignored during transmission of block data.
[See Also]
ESC p