Cisco Systems 1240AG Manual Do Utilizador

Página de 126
 
3-7
Cisco Aironet 1240AG Series Access Point Hardware Installation Guide
OL-8371-05
Chapter 3      Troubleshooting 1240AG Series Autonomous Access Points
Low Power Condition
Inline Power Status Messages
These messages are logged on the console port by the access point to report the power condition:
%CDP_PD-4-POWER_OK: Full Power - AC_ADAPTOR inline power source—This message 
indicates the access point is using the power module and can support full-power operation.
%CDP_PD-4-POWER_OK: Full Power - NEGOTIATED inline power source—This message 
indicates the access point is operating at full power and has successfully negotiated for 12.95 W of 
power from a Cisco switch supporting Cisco Intelligent Power Management.
%CDP_PD-4-POWER_OK: Full Power - HIGH_POWER_CLASSIC inline power source—This 
message indicates the access point is operating at full power because it has been configured for 
pre-standard compatibility mode and has detected a Cisco switch that does not support Intelligent 
Power Management but is able to supply sufficient power to the access point.
%CDP_PD-4-POWER_OK: Full Power - INJECTOR_CONFIGURED_ON_SOURCE inline power 
source—This message indicates the access point is operating at full power because it is connected 
to a Cisco switch that supports Intelligent Power Management and the switch has been configured 
with the power inline never command.
%CDP_PD-4-POWER_OK: Full power - INJECTOR_CONFIGURED_ON_CURRENT_PORT 
inline power source—This message indicates the access point is operating at full power because it 
has been configured to expect a power injector on this port. 
%CDP_PD-4-POWER_OK: Full Power - INJECTOR_DETECTED_PD inline power source—This 
message indicates the access point is operating at full power because it has detected a CDP packet 
from another Cisco powerable device (PD). The access point power is being supplied from a power 
injector or a non-Cisco power source because a Cisco power source does not transmit this type of 
CDP packet.
%CDP_PD-4-POWER_OK: Full Power - INJECTOR_DETECTED_MULTIPLE_MACS_ON_
HUB inline power source—This message indicates the access point is operating at full power 
because it has detected multiple Cisco devices. The access point power is being supplied from a 
power injector or a non-Cisco power source because a Cisco power source does not forward CDP 
packets. 
%CDP_PD-4-POWER_OK: Full Power - NON_CISCO-NO_CDP_RECEIVED inline power 
source—This message indicates the access point is operating at full power because it has not 
received any CDP packets within the timeout period. This condition indicates your access point is 
connected to a non-Cisco power source.
Note
To prevent possible over-current conditions, the power source must be an IEEE 802.3af 
compliant power source or an IEC60950 compliant limited power source.
%CDP_PD-2-POWER_LOW: All radios disabled - NEGOTIATED inline power source—This 
message indicates the access point is in low power mode with all radios disabled because the Cisco 
power source has indicated it is not capable of supplying sufficient power to the access point.
Note
A Cisco power injector might be required.